Backup Generator Sizing
Running watts, starting surge and the derates that decide the rated size — plus the two safety rules that matter more than any of the arithmetic.
Read this before any number on these pages.
Carbon monoxide kills people every storm season. Run a generator outdoors only, at least 20 feet from any door, window or vent, exhaust pointed away from the house. Not in a garage — not even with the door open. Fit CO alarms indoors and treat a headache during an outage as CO until proven otherwise.
And never back-feed. Plugging a generator into a wall socket energises the utility line outside and can kill a lineman restoring your power. It is illegal almost everywhere for exactly that reason. A transfer switch or interlock kit is the only correct connection, and it is an electrician's job.
Two numbers, not one
Running watts — everything on at once. Starting surge — the running load plus the inrush of the single largest motor, which draws about three times its running watts for a second or two.
Only one motor's surge is counted, and that is deliberate. Adding every motor's surge together, which is what most sizing tables do, buys a generator twice the size you need and burns fuel accordingly.
Then the derates
A generator should not run continuously above 80% of its rating, because heat is what ends them. Fuel costs output: propane about 10% against gasoline on the same engine, natural gas about 20%. Altitude costs about 3% per 1,000 feet.
Fuel choice is a storage decision
Gasoline makes the most power and stores worst — stabilizer and rotation. Propane stores indefinitely. Natural gas never runs out but needs a gas line. Diesel lasts longest and starts worst in cold.
Inverter or conventional
Inverter units are quieter, produce clean power for electronics and throttle down under light load. They cost more per watt and top out lower. For a fridge, a furnace fan and lights they are the better buy; for a well pump and central air they are not.
1 article
Generator size for 8000 running watts with a 1 HP motor on propane
| Running wattseverything on at once | 8,000W |
|---|---|
| Starting surgerunning load plus the 1 HP motor's inrush | 9,492W |
| After the 80% rulea generator should not run continuously above 80% of its rating | 10,000W |
| Propane deratestores indefinitely; about 10% less output than petrol | −10% |
| Altitude derate2,000 ft at 3% per 1,000 ft | −6% |
| Rated size needed | 11,820W |
| Nearest size sold1% headroom left | 12,000W |
Notes
- Carbon monoxide kills people every storm season. Run it outdoors only, at least 20 feet from any door, window or vent, with the exhaust pointed away from the house. Not in a garage — not even with the door open. Fit CO alarms indoors, and treat a headache during a power cut as CO until proven otherwise.
- Never back-feed. Plugging a generator into a wall socket to power the house energises the utility line outside and can kill a lineman working to restore your power. It is illegal almost everywhere for that reason. A transfer switch or an interlock kit is the only correct connection, and it is an electrician's job.
- Only the largest motor's inrush is counted, and that is deliberate. A 1 HP induction motor draws about 2,238 W for a second or two on start — roughly three times its running draw. Adding every motor's surge together, which is what most sizing tables do, buys you a generator twice the size you need and burns fuel accordingly.
- Propane: stores indefinitely; about 10% less output than petrol. The 10% derate is real — the same engine makes less power on this fuel, and it is already in the number above.
- The 80% rule is not caution. A generator held at its nameplate rating runs hot, and heat is what ends them. Sizing to 10,000 W of rated capacity for 8,000 W of load is what the machine is designed around.
- Inverter generators change the arithmetic. They are quieter, produce clean power for electronics, and throttle down under light load — but they cost more per watt and top out lower. For a fridge, a furnace fan and some lights, an inverter unit is usually the better buy; for a well pump and central air, it usually is not.
Backup generator size
232 calculations · browse all
- Generator size for 1000 running watts with a none HP motor on gasoline
- Generator size for 1000 running watts with a 1½ HP motor on gasoline
- Generator size for 1500 running watts with a ½ HP motor on gasoline
- Generator size for 1500 running watts with a 3 HP motor on gasoline
- Generator size for 2000 running watts with a 1 HP motor on gasoline
- Generator size for 2500 running watts with a none HP motor on gasoline
- Generator size for 2500 running watts with a 2 HP motor on gasoline
- Generator size for 3000 running watts with a ½ HP motor on gasoline
- Generator size for 3000 running watts with a 3 HP motor on gasoline
- Generator size for 3500 running watts with a 1 HP motor on gasoline
- Generator size for 4000 running watts with a none HP motor on gasoline
- Generator size for 4000 running watts with a 2 HP motor on gasoline
- Generator size for 4500 running watts with a ¾ HP motor on gasoline
- Generator size for 4500 running watts with a 3 HP motor on gasoline
- Generator size for 5000 running watts with a 1 HP motor on gasoline
- Generator size for 5500 running watts with a none HP motor on gasoline
- Generator size for 5500 running watts with a 2 HP motor on gasoline
- Generator size for 6000 running watts with a ¾ HP motor on gasoline
- Generator size for 6000 running watts with a 5 HP motor on gasoline
- Generator size for 6500 running watts with a 1 HP motor on gasoline
- Generator size for 7000 running watts with a none HP motor on gasoline
- Generator size for 7000 running watts with a 2 HP motor on gasoline
- Generator size for 7500 running watts with a ¾ HP motor on gasoline
- Generator size for 7500 running watts with a 5 HP motor on gasoline
- Generator size for 8000 running watts with a 1½ HP motor on gasoline
- Generator size for 8500 running watts with a none HP motor on gasoline
- Generator size for 8500 running watts with a 2 HP motor on gasoline
- Generator size for 9000 running watts with a ¾ HP motor on gasoline
- Generator size for 9000 running watts with a 5 HP motor on gasoline
- Generator size for 9500 running watts with a 1½ HP motor on gasoline
- Generator size for 10000 running watts with a ½ HP motor on gasoline
- Generator size for 10000 running watts with a 2 HP motor on gasoline
- Generator size for 10500 running watts with a ¾ HP motor on gasoline
- Generator size for 10500 running watts with a 5 HP motor on gasoline
- Generator size for 11000 running watts with a 1½ HP motor on gasoline
- Generator size for 11500 running watts with a ½ HP motor on gasoline
- Generator size for 11500 running watts with a 3 HP motor on gasoline
- Generator size for 12000 running watts with a ¾ HP motor on gasoline
- Generator size for 12000 running watts with a 5 HP motor on gasoline
- Generator size for 12500 running watts with a 1½ HP motor on gasoline
- Generator size for 13000 running watts with a ½ HP motor on gasoline
- Generator size for 13000 running watts with a 3 HP motor on gasoline
- Generator size for 13500 running watts with a 1 HP motor on gasoline
- Generator size for 13500 running watts with a 5 HP motor on gasoline
- Generator size for 14000 running watts with a 1½ HP motor on gasoline
- Generator size for 14500 running watts with a ½ HP motor on gasoline
- Generator size for 14500 running watts with a 3 HP motor on gasoline
- Generator size for 15000 running watts with a 1 HP motor on gasoline
Backup Generator vs Solar Battery — Cost per Hour of Outage CoveredA battery is cheaper to own and runs out. A generator is cheaper to run and never does. Which one wins is decided by how long your outages actually last.