Inverters
Inverter sizing works in opposite directions depending on the system.
Off-grid: size to the load
Continuous rating covers everything running at once, with margin — an inverter run continuously at its rating runs hot and dies early, so 80% is a sensible ceiling.
Surge rating covers the inrush of the largest motor, which draws roughly three times its running watts for a second or two.
Count one motor's surge, not the sum of all of them. Two large motors starting in the same half-second is unlikely, and sizing for it buys an inverter twice the size you need.
Grid-tied: size below the array, on purpose
A DC-to-AC ratio of about 1.2 is standard — 6 kW of panels on a 5 kW inverter.
An array reaches nameplate only in ideal conditions for a few hours a year. An inverter sized to that rare peak spends its life underloaded, where it is both expensive and less efficient. Clipping the top of the curve on the brightest days costs 1 to 3% of annual production, which is cheaper than the larger inverter.
Ratios of 1.3 to 1.4 suit east-west arrays and shallow tilts, where the curve is flatter and the peak lower.
String, micro or optimisers
The decision is almost entirely about shading.
A string inverter is cheapest per watt and a shaded panel drags its whole string down. Microinverters make each panel independent and put the electronics on the roof. Optimisers are the middle path: per-panel tracking, one central inverter.
On an unshaded south roof, a string inverter is fine and cheaper. With any partial shading, per-panel electronics recover more than they cost — and shade should be surveyed, not guessed.
Pure sine, always
Modified sine runs resistive loads and mistreats everything else. The price gap no longer justifies it in a permanent installation.
Hybrid capability is a decision you make once
Retrofitting a battery to a plain grid-tied string inverter usually means replacing the inverter. The premium for a hybrid-capable unit at purchase is far smaller than that replacement.
2 articles
String Inverter or Microinverters? Shade and Roof Shape Decide, Not PriceOn a clean south-facing roof with no shade, a string inverter is cheaper and there is little to argue about. Almost no roof is that roof.
Inverter Sizing: Continuous Watts, Surge Watts, and the DC-to-AC RatioTwo different numbers size an inverter, and a third one decides whether it should be smaller than the array on purpose.