ArrayBudgetPanels, batteries and inverters sized to the load you actually have.

Generator size for 8000 running watts with a none HP motor on gasoline

Generator size
10,000watts
8,000 W running on gasoline
Three numbers, not one8,000 Wrunningeverything on8,000 Wstarting surgelargest motor10,000 Wgeneratorrated sizeOnly the largest motor’s surge is counted — adding them all doubles the machine
Running wattseverything on at once8,000W
Starting surgeno motor load entered8,000W
After the 80% rulea generator should not run continuously above 80% of its rating10,000W
Gasoline deratehighest output, but stores badly — stabiliser and rotation needednone
Rated size needed10,000W
Nearest size sold0% headroom left10,000W
Running watts
8000 W
Largest motor
none HP
Fuel
gasoline
Altitude
0 ft

Read this before the numbers

Carbon monoxide kills people every storm season. Outdoors only, at least 20 feet from any door, window or vent, exhaust pointed away from the house. Not in a garage, not even with the door open. Fit CO alarms indoors and treat a headache during an outage as CO until proven otherwise.

Never back-feed. Plugging a generator into a wall socket energises the utility line outside and can kill a lineman restoring your power. A transfer switch or interlock kit is the only correct connection, and it is an electrician's job.

Two numbers, not one

8,000 W running — everything on at once. 8,000 W starting — the running load plus the inrush of the single largest motor.

Only one motor's surge is counted, and that is deliberate. A motor draws about three times its running watts for a second or two on start; adding every motor's surge together, which is what most sizing tables do, buys a generator twice the size you need.

Then the derates

The 80% rule first: a generator should not run continuously above 80% of its rating, because heat is what ends them. Then fuel — gasoline costs 0% of output against gasoline on the same engine. Then altitude, about 3% per 1,000 ft.

That comes to 10,000 W of rated capacity, so the size to buy is 10,000 W, leaving 0% headroom.

Inverter or conventional

Inverter generators are quieter, produce clean power for electronics, and throttle down under light load. They cost more per watt and top out lower. For a fridge, a furnace fan and lights, an inverter unit is usually the better buy. For a well pump and central air, it usually is not.

Fuel choice is a storage decision

Gasoline makes the most power and stores the worst — it needs stabilizer and rotation. Propane stores indefinitely and costs about 10% of output. Natural gas never runs out but costs 20% and needs a gas line. Diesel lasts longest and starts worst in cold.

Notes

  • **Carbon monoxide kills people every storm season.** Run it outdoors only, at least 20 feet from any door, window or vent, with the exhaust pointed away from the house. Not in a garage — not even with the door open. Fit CO alarms indoors, and treat a headache during a power cut as CO until proven otherwise.
  • **Never back-feed.** Plugging a generator into a wall socket to power the house energises the utility line outside and can kill a lineman working to restore your power. It is illegal almost everywhere for that reason. A transfer switch or an interlock kit is the only correct connection, and it is an electrician's job.
  • No motor load entered. If a well pump, air conditioner, compressor or refrigerator will be on this generator, add it — a motor's starting surge is about three times its running watts, and it is what actually decides the size.
  • Gasoline: highest output, but stores badly — stabiliser and rotation needed.
  • The 80% rule is not caution. A generator held at its nameplate rating runs hot, and heat is what ends them. Sizing to 10,000 W of rated capacity for 8,000 W of load is what the machine is designed around.
  • Inverter generators change the arithmetic. They are quieter, produce clean power for electronics, and throttle down under light load — but they cost more per watt and top out lower. For a fridge, a furnace fan and some lights, an inverter unit is usually the better buy; for a well pump and central air, it usually is not.